Part no.: 09 0432 601 04
M12 Female receptacle, Contacts: 4, shieldable, SMT, IP67, for SMT
M12-A, series 713, Automation Technology - Sensors and Actuators
This female receptacle with screw locking and a pin count of 4 is according to its protection class IP67 Dust-tight and has complete protection against contact and protection against temporary immersion. It can be used in areas with a pollution degree of 3. In places where contamination can occur that is conductive or can become conductive through condensation. With temperatures ranges of -40 °C/85 °C is this shieldable M12-A coded female receptacle designed for both severe cold and severe heat. Due to the qualified rated voltage of 250 V and the rated current of 4,0 A it is perfectly tuned for its field of application. It complies with the type standard DIN EN 61076-2-101.
General features
MorelessPart no. | 09 0432 601 04 |
Connector design | Female receptacle |
Type standard | DIN EN 61076-2-101 |
Version | Connector socket straight |
Connector locking system | screw |
Termination | SMT |
Degree of protection | IP67 |
Temperature range from/to | -40 °C / 85 °C |
Mechanical operation | > 100 Mating cycles |
Weight (g) | 1.75 |
Customs tariff number | 85369010 |
Country of Origin | DE |
Electrical parameters
MorelessRated voltage | 250 V |
Rated voltage UL | 2467 |
Rated impulse voltage | 2500 V |
Rated current | 4.0 A |
Insulation resistance | > 108 Ω |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | III |
EMC compliance | shieldable |
Shield connection | Shielding plate |
Material
MorelessContact body material | LCP |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
REACH SVHC |
CAS 7439-92-1 (Lead) |
SCIP number | b11e8b46-1fd0-44dd-9571-d31f07b4e0a4 |
Classifications
MorelesseCl@ss 11.1 | 27-44-01-09 |
ETIM 9.0 | EC003569 |
General Disclaim Notice
- The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
Downloads
Data sheet
Data sheet 09 0432 601 04
download
REACH
09 0432 601 04
download
RoHS
09 0432 601 04
download
China RoHS
09 0432 601 04
download
CAD files
Select required format