Menu
Back
  1. Products
  2. Subminiature connectors
  3. Snap-in IP40
  4. Snap-In Female cable connector, Contacts: 3, 3.6 mm, unshielded, solder, IP40
Part no.: 09 9748 00 03

Snap-In Female cable connector, Contacts: 3, 3.6 mm, unshielded, solder, IP40

Snap-In IP40, series 719, Subminiature Connectors
Available numbers of contacts
Compare product
Downloads
This female cable connector with snap-in locking system and a pin count of 3 is according to its protection class IP40 protected against solid foreign bodies and against access with a wire. No protection against water. It can be used in areas with a pollution degree of 1. In places where there is no or only slight, but non-conductive soiling. The pollution has no influence. With temperatures ranges of -25 °C/70 °C is this unshieldede Snap-In IP40 female cable connector designed for both severe cold and severe heat. Due to the qualified rated voltage of 60 V and the rated current of 3,0 A it is perfectly tuned for its field of application.
General features
Moreless
Part no. 09 9748 00 03
Connector design Female cable connector
Version Connector socket straight
Connector locking system snap-in
Termination solder
Degree of protection IP40
Cross-sectional area 0.25 mm² / AWG 24
Cable outlet 3.6 mm
Temperature range from/to -25 °C / 70 °C
Mechanical operation > 100 Mating cycles
Weight (g) 0.80
Customs tariff number 85369010
Country of Origin DE
Rated voltage 60 V
Rated impulse voltage 800 V
Rated current 3,0 A
Insulation resistance ≥ 1010 Ω
Pollution degree 1
Overvoltage category II
Insulating material group III
EMC compliance unshielded
Housing material PA
Contact body material PA
Contact material CuSn (bronze)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 57bd26ee-4d09-474d-bb4a-2763543ebc00
eCl@ss 11.1 27-44-01-09
ETIM 9.0 EC003569
Low Voltage Directive 2014/35/EU (EN 60204-1:2018;EN 60529:1991)
General Disclaim Notice
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
Downloads
Data sheet
Data sheet 09 9748 00 03
PDF
REACH
09 9748 00 03
PDF
RoHS
09 9748 00 03
PDF
China RoHS
09 9748 00 03
PDF
Declaration of conformity, Low Voltage Directive
Declaration of conformity
Low Voltage Directive
PDF
UKCA declaration of conformity, Electrical Equipment
UKCA declaration of conformity
Electrical Equipment
PDF
CAD files
Select required format
Snap-in IP40
09 9748 00 03