Part no.: 99 0641 10 05
M12 Male panel mount connector, Contacts: 4+FE, unshielded, THR, IP67, M16x1.5, front fastened
M12-L, series 823, Automation Technology - Voltage and Power Supply
This male panel mount connector mit M12x1 Verriegelung and a pin count of 5 is according to its protection class IP67 Dust-tight and has complete protection against contact and protection against temporary immersion. With temperatures ranges of -40 °C/105 °C is this unshielded M12-L coded male panel mount connector designed for both severe cold and severe heat. UL Due to the qualified rated voltage of 63 V and the rated current of 16,0 A it is perfectly tuned for its field of application. It complies with the type standard DIN EN IEC 61076-2-111:2018-10 and VDE 0687-76-2-111:2018-10.
General features
MorelessPart no. | 99 0641 10 05 |
Connector design | Male panel mount connector |
Type standard | DIN EN IEC 61076-2-111:2018-10;VDE 0687-76-2-111:2018-10 |
Version | Connector pin straight |
Connector locking system | M12x1 |
Termination | THR |
Degree of protection | IP67 |
Temperature range from/to | -40 °C / 105 °C |
Mechanical operation | > 100 Mating cycles |
Weight (g) | 16.62 |
Customs tariff number | 85369010 |
Country of Origin | DE |
Electrical parameters
MorelessRated voltage | 63 V |
Rated impulse voltage | 1500 V |
Rated current | 16.0 A |
Insulation resistance | > 1010 Ω |
Overvoltage category | III |
Insulating material group | II |
EMC compliance | unshielded |
Material
MorelessHousing material | Zinc die-cast nickel-plated |
Contact body material | PA (UL94 V-0) |
Contact material | CuZn (brass) / CuSn (bronze) |
Contact plating | Au (gold) |
Locking material | Zinc die-cast nickel-plated |
REACH SVHC |
CAS 7439-92-1 (Lead) |
SCIP number | 39661207-49d4-4644-957c-a8aacc10fd2d |
Classifications
MorelesseCl@ss 11.1 | 27-44-01-02 |
ETIM 9.0 | EC002635 |
General Disclaim Notice
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).