Part no.: 77 0627 0000 50704-0200
M12 Male angled connector, Contacts: 4, unshielded, moulded on the cable, IP68, PUR, black, 4 x 1.50 mm², 2 m
M12-T, series 813, Automation Technology - Voltage and Power Supply
This male angled connector with screw locking and a pin count of 4 is according to its protection class IP68 Dustproof and complete protection against contact. Protection against permanent submersion. Unless otherwise specified, protection up to 1 meter water depth. It can be used in areas with a pollution degree of 3. In places where contamination can occur that is conductive or can become conductive through condensation. With temperatures ranges of -40 °C/85 °C is this unshielded M12-T coded male angled panel mount connector designed for both severe cold and severe heat. Due to the qualified rated voltage of 63 V and the rated current of 12,0 A it is perfectly tuned for its field of application. It complies with the type standard DIN EN IEC 61076-2-111:2018-10 and VDE 0687-76-2-111:2018-10.
General features
MorelessPart no. | 77 0627 0000 50704-0200 |
Connector design | Male angled connector |
Type standard | DIN EN IEC 61076-2-111:2018-10;VDE 0687-76-2-111:2018-10 |
Cable length | 2 m (Standard 2 m and 5 m. Other lengths are available on request.) |
Version | Connector pin angled |
Connector locking system | screw |
Termination | moulded on the cable |
Degree of protection | IP68 |
Connection cross-section | 1.50 mm² / AWG 16 |
Temperature range from/to | -40 °C / 85 °C |
Mechanical operation | > 100 Mating cycles |
Weight (g) | 449.98 |
Customs tariff number | 85444290 |
Electrical parameters
MorelessRated voltage | 63 V |
Rated impulse voltage | 1500 V |
Rated current | 12.0 A |
Pollution degree | 3 |
Overvoltage category | III |
Insulating material group | II |
EMC compliance | unshielded |
Material
MorelessHousing material | PUR |
Contact body material | PUR black |
Contact material | CuZn (brass) / CuSn (bronze) |
Contact plating | Au (gold) |
REACH SVHC |
CAS 7439-92-1 (Lead) |
SCIP number | e8182282-75ed-45b1-b7f9-fe38b48d50a6 |
Classifications
MorelesseCl@ss 11.1 | 27-06-03-11 |
ETIM 9.0 | EC002638 |
Declarations of conformity
MorelessLow Voltage Directive | 2014/35/EU (EN 60529:1991;EN 60204-1:2018) |
RoHS Directive | 2011/65/EU (EN 50581:2012) |
Cable data
MorelessStructure of the cable | |
Cable diameter | 8.0 mm |
Cross section | 4 x 1.50 mm² |
Sheath material | PUR |
Single-lead insulation | PP |
Single-lead structure | 84 x 0.15 mm |
Cable color | black |
Electrical properties | |
Conductor resistance | 13.3 Ω/Km (20°C) |
Mechanical properties | |
Bending radius, fixed cable | ≥ 7.5 x Ø |
Bending radius, moving cable | ≥ 10 x Ø |
Bending cycles | 5 million |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 20 m |
Travel speed | ≤ 300 m/min |
Thermal properties | |
Temperature range cable in move from/to | -30 °C / 80 °C |
Temperature range cable fixed from/to | -50 °C / 80 °C |
Other features | |
Halogen free | yes |
General Disclaim Notice
- The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
- The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
- Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
- Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Downloads
Data sheet
Data sheet 77 0627 0000 50704-0200
download
REACH
77 0627 0000 50704-0200
download
RoHS
77 0627 0000 50704-0200
download
China RoHS
77 0627 0000 50704-0200
download
Declaration of conformity
Low Voltage Directive
download
UKCA declaration of conformity
Electrical Equipment
download
Declaration of conformity
RoHS Directive
download
UKCA declaration of conformity
UK-RoHS
download
CAD files