Menu
Back
  1. Products
  2. Automation technology - Voltage and Power Supply
  3. M12-T
  4. M12 Male cable connector, Contacts: 4, unshielded, moulded on the cable, IP68, PUR, black, 4 x 1.50 mm², 2 m
Part no.: 77 0629 0000 50704-0200

M12 Male cable connector, Contacts: 4, unshielded, moulded on the cable, IP68, PUR, black, 4 x 1.50 mm², 2 m

M12-T, series 813, Automation Technology - Voltage and Power Supply
(Standard 2 m and 5 m. Other lengths are available on request.)
Compare product
Downloads
This male cable connector with screw locking and a pin count of 4 is according to its protection class IP68 Dustproof and complete protection against contact. Protection against permanent submersion. Unless otherwise specified, protection up to 1 meter water depth. It can be used in areas with a pollution degree of 3. In places where contamination can occur that is conductive or can become conductive through condensation. With temperatures ranges of -40 °C/85 °C is this unshielded M12-T coded male cable connector designed for both severe cold and severe heat. Due to the qualified rated voltage of 63 V and the rated current of 12,0 A it is perfectly tuned for its field of application. It complies with the type standard DIN EN IEC 61076-2-111:2018-10 and VDE 0687-76-2-111:2018-10.
General features
Moreless
Part no. 77 0629 0000 50704-0200
Connector design Male cable connector
Type standard DIN EN IEC 61076-2-111:2018-10;VDE 0687-76-2-111:2018-10
Cable length 2 m (Standard 2 m and 5 m. Other lengths are available on request.)
Version Connector pin straight
Connector locking system screw
Termination moulded on the cable
Degree of protection IP68
Cross-sectional area 1.50 mm² / AWG 16
Temperature range from/to -40 °C / 85 °C
Mechanical operation > 100 Mating cycles
Weight (g) 234.00
Customs tariff number 85444290
Rated voltage 63 V
Rated impulse voltage 1500 V
Rated current 12.0 A
Pollution degree 3
Overvoltage category III
Insulating material group II
EMC compliance unshielded
Housing material PUR
Contact body material PUR
Contact material CuZn (brass) / CuSn (bronze)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 21503551-d91e-4947-a4ba-f3c633b7258d
eCl@ss 11.1 27-06-03-11
ETIM 9.0 EC002638
Low Voltage Directive 2014/35/EU (EN 60529:1991;EN 60204-1:2018)
RoHS Directive 2011/65/EU (EN 50581:2012)
Cable data
Moreless
Structure of the cable
Cable diameter 8.0 mm
Cross section 4 x 1.50 mm²
Sheath material PUR
Single-lead insulation PP
Single-lead structure 84 x 0.15 mm
Cable color black
Electrical properties
Conductor resistance 13.3 Ω/Km (20°C)
Mechanical properties
Bending radius, fixed cable ≥ 7.5 x Ø
Bending radius, moving cable ≥ 10 x Ø
Bending cycles 5 million
Permitted acceleration 5 m/s²
Travel distance, horizontal 20 m
Travel speed ≤ 300 m/min
Thermal properties
Temperature range cable in move from/to -30 °C / 80 °C
Temperature range cable fixed from/to -50 °C / 80 °C
Other features
Halogen free yes
General Disclaim Notice
  1. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  2. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  3. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Downloads
Data sheet
Data sheet 77 0629 0000 50704-0200
PDF
REACH
77 0629 0000 50704-0200
PDF
RoHS
77 0629 0000 50704-0200
PDF
China RoHS
77 0629 0000 50704-0200
PDF
Declaration of conformity, Low Voltage Directive
Declaration of conformity
Low Voltage Directive
PDF
UKCA declaration of conformity, Electrical Equipment
UKCA declaration of conformity
Electrical Equipment
PDF
Declaration of conformity, RoHS Directive
Declaration of conformity
RoHS Directive
PDF
UKCA declaration of conformity, UK-RoHS
UKCA declaration of conformity
UK-RoHS
PDF
CAD files
Select required format
M12-T
77 0629 0000 50704-0200