This female cable connector with screw locking and a pin count of 8 (08-a) is according to its protection class IP67 Dust-tight and has complete protection against contact and protection against temporary immersion. It can be used in areas with a pollution degree of 1. In places where there is no or only slight, but non-conductive soiling. The pollution has no influence. With temperatures ranges of -25 °C/70 °C is this unshielded M16 IP67 female cable connector designed for both severe cold and severe heat. Due to the qualified rated voltage of 60 V and the rated current of 3,0 A it is perfectly tuned for its field of application. It complies with the type standard DIN EN 61076-2-106.
General features
Moreless
Part no. 79 6072 20 08
Connector design Female cable connector
Type standard DIN EN 61076-2-106
Cable length 2 m (Standard 2 m and 5 m. Other lengths are available on request.)
Version Connector socket straight
Connector locking system screw
Termination moulded on the cable
Degree of protection IP67
Cross-sectional area 0.25 mm² / AWG 24
Temperature range from/to -25 °C / 70 °C
Mechanical operation > 500 Mating cycles
Weight (g) 124.30
Customs tariff number 85444290
Country of Origin HU
Rated voltage 60 V
Rated impulse voltage 500 V
Rated current 3,0 A
Insulation resistance ≥ 1010 Ω
Pollution degree 1
Overvoltage category I
Insulating material group III
EMC compliance unshielded
Housing material PUR
Contact body material PBT (UL94 V-0)
Contact material CuSn (bronze)
Contact plating Au (gold)
REACH SVHC CAS-119-47-1 (2,2'-Methylenbis)
CAS 7439-92-1 (Lead)
SCIP number c7c6cb0a-c38f-4ec9-92ef-b8cd8f453dc8
eCl@ss 11.1 27-06-03-11
ETIM 9.0 EC002638
Low Voltage Directive 2014/35/EU (EN 60204-1:2018;EN 60529:1991)
RoHS Directive 2011/65/EU (EN 50581:2012)
Cable data
Moreless
Structure of the cable
Cable diameter 5.7 mm
Cross section 8 x 0.25 mm²
Sheath material PUR
Single-lead insulation PVC Y12
Single-lead structure 32 x 0.10 mm
Cable color black
Electrical properties
Conductor resistance 79.9 Ω/Km (20°C)
Mechanical properties
Bending radius, fixed cable ≥ 5 x Ø
Bending radius, moving cable ≥ 12 x Ø
Thermal properties
Temperature range cable in move from/to -5 °C / 70 °C
Temperature range cable fixed from/to -25 °C / 70 °C
Other features
Halogen free no
General Disclaim Notice
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. To protect against unintentional opening of the connector, the thread between the housing and the connector head must be secured with a suitable cyanoacrylate adhesive when used in circuits with voltages dangerous to the touch. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
  4. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  5. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  6. Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
  7. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
  8. To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Downloads
Data sheet
Data sheet 79 6072 20 08
PDF
REACH
79 6072 20 08
PDF
RoHS
79 6072 20 08
PDF
China RoHS
79 6072 20 08
PDF
Declaration of conformity, Low Voltage Directive
Declaration of conformity
Low Voltage Directive
PDF
UKCA declaration of conformity, Electrical Equipment
UKCA declaration of conformity
Electrical Equipment
PDF
Declaration of conformity, RoHS Directive
Declaration of conformity
RoHS Directive
PDF
UKCA declaration of conformity, UK-RoHS
UKCA declaration of conformity
UK-RoHS
PDF
CAD files
Select required format
M16 IP67
79 6072 20 08