This female panel mount connector with snap-in locking system and a pin count of 4 is according to its protection class IP40 protected against solid foreign bodies and against access with a wire. No protection against water. It can be used in areas with a pollution degree of 1. In places where there is no or only slight, but non-conductive soiling. The pollution has no influence. With temperatures ranges of -25 °C/70 °C is this unshieldede Snap-In IP40 female panel mount connector designed for both severe cold and severe heat. Due to the qualified rated voltage of 60 V and the rated current of 3,0 A it is perfectly tuned for its field of application.
General features
Moreless
Part no. 09 9766 20 04
Connector design Female panel mount connector
Version Connector socket straight
Connector locking system snap-in
Termination THT
Degree of protection IP40
Temperature range from/to -25 °C / 70 °C
Mechanical operation > 100 Mating cycles
Weight (g) 1.28
Customs tariff number 85369010
Country of Origin DE
Rated voltage 60 V
Rated impulse voltage 800 V
Rated current 3,0 A
Insulation resistance ≥ 1010 Ω
Pollution degree 1
Overvoltage category II
Insulating material group III
EMC compliance unshielded
Housing material PA
Contact body material PA
Contact material CuSn (bronze)
Contact plating Au (gold)
REACH SVHC CAS 7439-92-1 (Lead)
SCIP number 16a4af5e-0b5a-4115-a671-299684da0390
eCl@ss 11.1 27-44-01-09
ETIM 9.0 EC003569
General Disclaim Notice
  1. The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
  2. The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
  3. Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
  4. The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
  5. The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".