Part no.: 77 3634 3405 50004-0100
M8 Male cable connector - female angled connector M12x1, Contacts: 4, unshielded, moulded on the cable, IP67, PUR, black, 4 x 0.25 mm², with LED PNP closer, 1 m
series 765, Automation Technology - Sensors and Actuators
This female cable connector with with screw locking and a pin count of 4 is according to its protection class IP67 Dust-tight and has complete protection against contact and protection against temporary immersion. It can be used in areas with a pollution degree of 3. In places where contamination can occur that is conductive or can become conductive through condensation. With temperatures ranges of -25 °C/85 °C is this unshielded connecting cableen connecting cable designed for both severe cold and severe heat. Due to the qualified rated voltage of 60 V and the rated current of 4,0 A it is perfectly tuned for its field of application. It complies with the type standard DIN EN 61076-2-104.
General features
MorelessPart no. |
77 3634 3405 50004-0100
Alternative part no.: 79 5105 10 04
|
Notice |
Please note that, due to the change from the old to the new order number, there may be deviations in the technical specifications. For questions about product details, please use the ‘Contact Customer Service’ form on the right.
More |
Connector design | Male cable connector - female angled connector M12x1 |
Type standard |
DIN EN 61076-2-104 DIN EN 61076-2-101 |
Cable length | 1 m (Standard 1 m and 2 m. Other lengths are available on request.) |
Version | Connecting cable |
Connector locking system | screw |
Termination | moulded on the cable |
Degree of protection | IP67 |
Cross-sectional area | 0.34 mm² / AWG 24 |
Temperature range from/to | -25 °C / 85 °C |
Mechanical operation | > 100 Mating cycles |
Additional information | with LED PNP closer |
Weight (g) | 26 |
Customs tariff number | 85444290 |
Country of Origin | DE |
Electrical parameters
MorelessRated voltage | 60 V |
Rated impulse voltage | 1500 V |
Rated current | 4.0 A |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
EMC compliance | unshielded |
Material
MorelessHousing material | PUR |
Contact body material | PUR |
Contact material | CuZn (brass) / CuSn (bronze) |
Contact plating | Au (gold) |
Locking material | Zinc die-cast nickel-plated |
REACH SVHC |
CAS 7439-92-1 (Lead) |
SCIP number | b1edf2bb-66a8-43fc-8bf8-915d716c481c |
Classifications
MorelesseCl@ss 11.1 | 27-06-03-11 |
ETIM 9.0 | EC002638 |
Declarations of conformity
MorelessRoHS Directive | 2011/65/EU (EN 50581:2012) |
Cable data
MorelessStructure of the cable | |
Cable diameter | 4.5 mm |
Cross section | 4 x 0.25 mm² |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0.10 mm |
Cable color | black |
Electrical properties | |
Conductor resistance | 79.9 Ω/Km (20°C) |
Mechanical properties | |
Bending radius, fixed cable | ≥ 5 x Ø |
Bending radius, moving cable | ≥ 10 x Ø |
Bending cycles | 0.3 million |
Thermal properties | |
Temperature range cable in move from/to | -5 °C / 80 °C |
Temperature range cable fixed from/to | -25 °C / 80 °C |
Other features | |
Halogen free | no |
General Disclaim Notice
- The connector must not be plugged or unplugged under load. Non-observance and improper use can result in personal injury.
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- Connectors which are used in circuits with voltages dangerous to the touch may only be installed and used by, or under the supervision of, persons with electrical engineering training, taking into account the applicable regulations and standards.
- The user must take suitable safety precautions to ensure that the connector cannot be accidentally disconnected.
- Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
- The plug connector is not suitable for mains voltages Please observe the pollution degree and the overvoltage category. For further information, please refer to the download center "Technical Information".
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Downloads