Part no.: 99 0436 12 05
Female cable connector, Contacts: 5, 6.0-8.0 mm, unshielded, screw clamp, IP67, UL, PG 9
M12, series 713
General features
MorelessPart no. | 99 0436 12 05 |
Connector design | Female cable connector |
Type standard | DIN EN 61076-2-101 |
Version | Connector socket straight |
Connector locking system | screw |
Termination | screw clamp |
Degree of protection | IP67 |
Cross-sectional area | max. 0.75 mm² / AWG 18 |
Cable outlet | 6.0-8.0 mm |
Temperature range from/to | -40 °C / 85 °C |
Mechanical operation | > 50 Mating cycles |
Weight (g) | 25.60 |
Customs tariff number | 85369010 |
Electrical parameters
MorelessRated voltage | 60 V |
Rated impulse voltage | 1500 V |
Rated current (40 °C) | 4 A (3 A UL) |
Insulation resistance | > 10⁸ Ω |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | III |
EMC compliance | unshielded |
Material
MorelessHousing material | PA |
Contact body material | PA |
Contact material | CuZn (brass) |
Contact plating | CuSnZn (Optalloy) |
Locking material | Zinc die-cast nickel-plated |
REACH SVHC |
CAS 96-45-7 (Imidazolidine-2-thione) CAS 7439-92-1 (Lead) |
SCIP number | a37bc639-9ce0-4147-b4cd-2b465aa3ac24 |
Authorization/approvals
MorelessApprovals | UL |
Classifications
MorelesseCl@ss 11.1 | 27-44-01-02 |
ETIM 9.0 | EC002635 |
Declarations of conformity
MorelessLow Voltage Directive | 2014/35/EU (EN 60204-1:2018;EN 60529:1991) |
General Disclaim Notice
- The connectors have been developed for applications in plant engineering, control and electrical equipment construction. The user is responsible for checking whether the connectors can also be used in other areas of application.
- Plug connectors with enclosure protection IP67 and IP68 are not suitable for use under water. When used outdoors, the plug connectors must be protected separately against corrosion. For further information on the IP protection classes, please refer to the "Technical Information" download centre.
- To lock the cable connector with the device connector, the threaded ring is tightened "hand-tight" (approx. 60 cNm).
Downloads
Data sheet
Data sheet 99 0436 12 05
download
Certificates
UL certificate
download
REACH
99 0436 12 05
download
RoHS
99 0436 12 05
download
China RoHS
99 0436 12 05
download
Declaration of conformity
Low Voltage Directive
download
UKCA declaration of conformity
Electrical Equipment
download
CAD files
Select required format